THE EFFECT OF WEAR MECHANISM FOR PLASMA OXIDISED CP TI AND ITS ALLOYS ON TRIBOCORROSION PERFORMANCE

Yeşim SECER, Yusuf Burak BOZKURT, Halim KOVACI, Ali Fatih YETIM, Ayhan CELIK

Öz


THE EFFECT OF WEAR MECHANISM FOR PLASMA OXIDISED CP TI AND ITS ALLOYS ON TRIBOCORROSION PERFORMANCE

Abstract

 Commercially pure titanium (cp-Ti) and its alloys (Ti6Al4V, Ti45Nb, Ti6Al7Nb etc.) have an important use among biometallic materials. Recently developed alloying techniques and production methods have enabled many different titanium alloys to be used as biomaterials. Although harder and higher corrosion resistance than iron and its alloys, it is used as an invasive implant by applying various surface modifications to improve biodegradability performance. One of these processes is plasma oxidation process. With this process, corrosion resistance can be improved by obtaining more passive surfaces. There are many studies on these performance measurements in the literature. In this study, the effects of wear and corrosion mechanisms on the material in one cycle were investigated. Cp-Ti, Ti6Al4V and Ti45Nb were chosen as base materials. Samples were subjected to plasma oxidation for 600˚C-3 hours. Within the scope of this investigation, the adhesive wear mechanism on oxidized surfaces was compared with different types of abrasives, and its effect on corrosion performance was measured with the tribocorrosion test apparatus. Abrasion tests were carried out with two abrasive balls: tungsten carbide (WC) and silicon nitride (SiN) under 3 N load. Processes were carried out in two different media, dry and simulated body fluid (SBF). Potentiodynamic polarization scans were carried out using the scanning range of -0.28 V - 2 V in the presence of wear tests for tribocorrosion measurements. While abrasive wear mechanism is dominant in untreated samples, adhesive wear is at the forefront in coated samples. The effects that increase the corrosion resistance positively affected the performance of tribocorrosion. The high oxidation resistance of Ti and its alloys increased adhesive wear performance, and because of the higher corrosion resistance of Ti6Al4V and Ti45Nb, which were alloyed from these three material groups, their corrosion performance was higher than Cp-Ti.

Keywords: Cp-Ti, Ti6Al4V, Ti45Nb, Plasma oxidation, Tribocorrosion.


Anahtar Kelimeler


Cp-Ti, Ti6Al4V, Ti45Nb, Plasma oxidation, Tribocorrosion.

Tam Metin:

PDF (English)

Referanslar


Sha, W. and Malinov, S., 2009. Titanium Alloys: Modelling of Microstructure, Properties and Applications. CRC Press.

Habibovic, P., Li, J., Van Der Valk, C. M., Meijer, G., Layrolle, P., Van Blitterswijk, C. A., & De Groot, K. (2005). Biological performance of uncoated and octacalcium phosphate-coated Ti6Al4V. Biomaterials, 26(1), 23-36.

Fu, Y. and Batchelor, A.W., 1998. Laser nitriding of pure titanium with Ni, Cr for improved wear performance. Wear, 214 (1), 83-90.

Kovacı, H. (2019). Comparison of the microstructural, mechanical and wear properties of plasma oxidized Cp-Ti prepared by laser powder bed fusion additive manufacturing and forging processes. Surface and Coatings Technology, 374, 987-996.

Pan, J., Leygraf, C., Thierry, D., & Ektessabi, A. M. (1997). Corrosion resistance for biomaterial applications of TiO2 films deposited on titanium and stainless steel by ion‐beam‐assisted sputtering. Journal of Biomedical Materials Research: An Official Journal of The Society for Biomaterials and The Japanese Society for Biomaterials, 35(3), 309-318.

Yao, Z., Jiang, Z., & Wang, F. (2007). Study on corrosion resistance and roughness of micro-plasma oxidation ceramic coatings on Ti alloy by EIS technique. Electrochimica acta, 52(13), 4539-4546.

Alsaran, A., Çelik, A., Efeoğlu, İ., Baran,Ö., Albayrak,Ç., 2010. Çeşitli Oksidasyon İşlemleriyle Oksit Kaplanan Ti6Al4V’ un Yapay Vücut Sıvısı İçinde (SBF) Sürtünme ve Aşınma Özellikleri. 5. Ulusal Biyomekanik Kongresi, İzmir.

Guleryuz, H. and Cimenoglu, H., 2004. Effect of thermal oxidation on corrosion and corrosion-wear behaviour of a Ti-6A1-4V alloy. Biomaterials, 25 (16), 3325- 3333.

Lopez, M.F., Jimenez, J.A. and Gutierrez, A., 2003. Corrosion study of surfacemodified vanadium-free titanium alloys. Electrochimica Acta, 48 (10), 1395- 1401.

Kokubo T, Takamada H. How useful is SBF in predicting in vivo bone bioactivity? Biomaterials, 2006, 27, 2907–2915.

Bayrak, Ö., 2007. Plazma ile nitrürlenmiĢ CoCrMo implant malzemenin yapısal ve tribolojik özelliklerinin incelenmesi. MsC Thesis, Atatürk Üniversitesi, Fen Bilimleri Enstitüsü.

A.F. Yetim, Doctoral dissertation, Phd Thesis, Atatürk University Graduate School of Naturel and Applied Sciences, (2009) 62,63.

M.H. Staia, A. Fragiel, J. Machado, S.P. Brühl, B.J. Gomez, Surface Engineering, 15 (1999) 313-316.

Kovacı, H., & Seçer, Y. (2020). Improved tribological performance of AISI 316L stainless steel by a combined surface treatment: Surface texturing by selective laser melting and plasma nitriding. Surface and Coatings Technology, 126178.


Madde Ölçümleri

Ölçüm Çağırılıyor ...

Metrics powered by PLOS ALM

Refback'ler

  • Şu halde refbacks yoktur.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Selçuk-Teknik Dergisi  ISSN:1302-6178